Mike's Workshop Manuals: Service manuals for every vehicle
Home >> Ford >> 2009 >> Edge SE, AWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 1740 (HVAC Climate Control System - General Information And Diagnostics) >> General Procedures >> Refrigerant Oil Adding >> Adding Refrigerant Oil After Multiple Component Replacement After A/C System Contamination

Adding Refrigerant Oil After Multiple Component Replacement After A/C System Contamination

WARNING: This page is about a different car, the 2009 Ford RV Cutaway, 2009 Ford Econoline, 2009 Ford E450 Super Duty, and 2009 Ford Cutaway. However, it is still accessible from the selected car via links, so may be relevant.
NOTE: This refrigerant oil adding method is to be used when a new A/C compressor, suction accumulator or receiver drier and evaporator core orifice or TXV  have been installed due to system contamination and the A/C system has been flushed.
  1. If the new A/C compressor is shipped with a new clutch and pulley already installed, remove the shipping caps and rotate the new A/C compressor shaft 6 to 8 revolutions while collecting the oil in a clean measuring cup.
  2. Add 60 ml (2 fl oz) directly to the new A/C compressor suction port.
  3. Inject the total vehicle PAG oil capacity minus 60 ml (2 fl oz) to the low-side service port during system charging. For the total PAG oil capacity specification, refer to the SPECIFICATIONS .