P0133 - O2 Circuit Slow Response (Bank 1, Sensor 1)
P0133 - O2 CIRCUIT SLOW RESPONSE (BANK 1, SENSOR 1)
| Description: | The heated oxygen sensor (HO2S) monitor checks the HO2S frequency and amplitude. The test fails if the frequency and amplitude fall below a calibrated limit during testing. | |||
| Possible Causes: |
|
|||
| Diagnostic Aids: | Access the HO2S test results from the generic OBD menu to verify the DTC. | |||
| Application | Key On Engine Off | Key On Engine Running | Continuous Memory | |
| All | - | - | refer to PINPOINT TEST DW . | |