Mike's Workshop Manuals: Service manuals for every vehicle
Home >> Ford >> 2007 >> Crown Victoria Police Interceptor >> Repair and Diagnosis (Single Page) >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Climate Control System - General Information And Diagnostics >> General Procedures >> Spring Lock Coupling >> Disconnect

Spring Lock Coupling: Disconnect

  1. Remove the A/C tube lock coupling clip, if equipped.
  2. Fig 1: A/C Tube Lock Coupling Clip
    GF0014360Courtesy of FORD MOTOR CO.
  3. Fit the special tool to the spring lock coupling.
  4. Fig 2: Special Tool For Spring Lock Coupling
    GF0014361Courtesy of FORD MOTOR CO.
  5. Push the tool into the cage opening to release the female fitting from the A/C tube lock coupling spring.
  6. Fig 3: Pushing Tool Into Cage
    GF0014362Courtesy of FORD MOTOR CO.
  7. Pull the spring lock coupling fittings apart.
  8. Fig 4: Pulling Spring Lock Coupling Fittings Apart
    G03889982Courtesy of FORD MOTOR CO.
    CAUTION: Do not use metal tools to remove the O-ring seals. They can cause axial scratches across the O-ring seal grooves, resulting in refrigerant leaks.
  9. Remove the O-ring seals with a non-metallic tool.
  10. Fig 5: Identifying O-Ring Seals
    G03945165Courtesy of FORD MOTOR CO.
    CAUTION: Do not use a screwdriver or similar tool to remove the A/C tube lock coupling spring; this can cause axial scratches across the O-ring seal grooves resulting in refrigerant leaks.
  11. Remove the A/C tube lock coupling spring with a small hooked wire.
  12. Fig 6: Identifying Spring Lock Coupling Spring
    G03915811Courtesy of FORD MOTOR CO.