Catalyst Efficiency Monitor Overview

The catalyst efficiency monitor uses precatalyst and post catalyst heated oxygen sensors (HO2S) to infer the hydrocarbon (HC) efficiency based on the oxygen storage capacity of the catalyst. Under normal, closed-loop fuel conditions, high efficiency catalysts have significant oxygen storage. This makes the switching frequency of the post catalyst HO2S (B) very slow and reduces the amplitude of those switches as compared to the switching frequency and amplitude of the precatalyst HO2S (A). As catalyst efficiency deteriorates due to thermal and chemical deterioration, its ability to store oxygen declines. The post catalyst HO2S (B) signal begins to switch more rapidly with increasing amplitude, approaching the switching frequency and amplitude of the precatalyst HO2S (A).

For additional information on the catalyst efficiency monitor and exhaust systems, refer to CATALYST AND EXHAUST SYSTEM .

Fig 1: Identifying High Catalyst Efficiency
G04587212Courtesy of FORD MOTOR CO.
Fig 2: Identifying Low Catalyst Efficiency
G04587213Courtesy of FORD MOTOR CO.