Non-Emission Freeze Frame Data Table
NON-EMISSION FREEZE FRAME DATA TABLE
| Acronym | Description | Measurement Units |
|---|---|---|
| DTCFZ | Frozen DTC detailed number | Decimal |
| RPM | Engine speed | RPM |
| TFT | Transaxle fluid temperature | Degrees |
| M_SPEED | Traction motor speed | RPM |
| G_INV_V | Generator inverter voltage | Volts |
| M_PHTMP | The highest traction motor inverter temperature within the 3 phases | Degrees |
| MCLTEMP | Traction motor coil temperature | Degrees |
| G_PHTMP | The highest generator motor inverter temperature within the 3 phases | |
| GCLTEMP | Generator motor coil temperature | Degrees |
| G_SPEED | Generator motor speed | RPM |
| TQ_DSD | Desired Total torque | Nm |
| MTQ_CMD | Desired traction motor torque | Nm |
| GTQ_OUT | Desired generator motor torque | Nm |
| CONTACT | Traction battery contactor status TCM received | Open/Closed |
| ABS_STAT | ABS system status TCM received | Activated/Not Activated |
| G_SDN_A | Generator motor shutdown TCM received | On/Off |
| M_SDN_C | Generator motor shutdown TCM received | On/Off |
| M_SDN_A | Traction motor shutdown TCM received | On/Off |
| M_SDN_C | Traction motor shutdown TCM received | On/Off |
| HVINTLCK | High voltage interlock circuit status | On/Off |
| TCM_HAZ | Hazard indicator commanded | On/Off |
| TCM_CAU | Caution indicator commanded | On/Off |
| PRNDL_T | Gear selector position TCM received | Selector position |
| IMECT | Motor electronics coolant temperature TCM received | Degrees |