Exhaust System Backpressure
Connect scan tool. Start and run engine until a temperature of 170°F is reached. Disconnect engine oil temperature sensor. Run engine at wide open throttle and monitor EBP PID on scan tool. If pressure exceeds 34 PSI at 3400 RPM, exhaust system is restricted.