Mike's Workshop Manuals: Service manuals for every vehicle
Home >> Ford >> 2000 >> Contour SVT >> Repair and Diagnosis >> External Pages >> Different car >> Section 238 (Charging System - (Generator & Regulators)) >> System Tests >> Test B: Warning Indicator Is On With Engine Running, System Is Not Charging

Test B: Warning Indicator Is On With Engine Running, System Is Not Charging

WARNING: This page is about a different car, the 2004 Ford Ranger. However, it is still accessible from the selected car via links, so may be relevant.

  1. Check Generator B+ Circuit (Black/Orange Wire)

    Measure voltage between ground and generator terminal B+ (Black/Orange wire). See Figure. Is the voltage equal to battery voltage? If yes, go to next step. If no, repair Black/Orange wire between generator and battery junction box. See WIRING DIAGRAMS .
  2. Check "A" Circuit (Yellow/White Wire)

    Disconnect generator 3-pin harness connector. Measure voltage between ground and generator harness connector terminal No. 3 (Yellow/White wire). See Fig 1 or Fig 2 . Is the voltage equal to battery voltage? If yes, go to next step. If no, repair Yellow/White wire between battery and generator. See WIRING DIAGRAMS .
  3. Check "I" Circuit (Light Green/Red Wire) For An Open

    Turn ignition on. Measure voltage between ground and generator harness connector terminal No. 1 (Light Green/Red wire). See Fig 1 or Fig 2 . Is the voltage equal to battery voltage? If yes, go to next step. If no, repair Light Green/Red wire between generator connector and instrument cluster. See WIRING DIAGRAMS .
  4. Check For Voltage Drop In B+ Circuit (Black/Orange Wire)

    Turn ignition off. Connect generator 3-pin harness connector. Start engine and let idle. With the engine running, turn the headlamps on and the blower motor to the high position. With the engine at 2000 RPM, measure the voltage drop between the generator B+ terminal (Black/Orange wire) and the positive battery terminal. See Figure. Is the voltage drop less than 0.5 volt? If yes, for 2.3L engine, replace generator. See GENERATOR  under REMOVAL & INSTALLATION. For 3.0L and 4.0L engines, go to next step. If no, repair Black/Orange wire between generator and battery. See WIRING DIAGRAMS .
  5. Check Generator Integrity

    With the engine running at approximately 2000 RPM, full field the generator by grounding the "F" (field) terminal on the voltage regulator. See Figure. Did the charging system achieve approximately 75 percent of full output? If yes, install a new voltage regulator. See VOLTAGE REGULATOR  under REMOVAL & INSTALLATION. Test the system for normal operation. If no, install a new generator. See GENERATOR  under REMOVAL & INSTALLATION. Test the system for normal operation.
Fig 1: Identifying Generator 3-pin Connector Terminals (2.3L)
G00046837Courtesy of FORD MOTOR CO.
Fig 2: Identifying Generator 3-pin Connector Terminals (3.0L & 4.0L)
G00264287Courtesy of FORD MOTOR CO,