Door Key Cylinder Switch (Probe)
- Remove door trim panel of switch to be tested. Disconnect switch connector. Insert key into outside door lock. With key in neutral position, no continuity should exist between Blue/Red wire and Green/Black wire terminals at door key cylinder switch. See WIRING DIAGRAMS .