Spring Lock Coupling Clamp Table: Installation
- Ensure replacement orifice tube is same color as that removed. Lubricate "O" rings on orifice tube with clean refrigeration oil. Place orifice tube into orifice tube remover/installer. Insert orifice tube into evaporator inlet tube until orifice tube bottoms against the stop.