Test Kc: Step 6
6) Check Solenoids For Vacuum Cycling Connect vacuum pump to AM1 solenoid vacuum supply port. Connect vacuum gauge to output port. Maintain vacuum at source while depressing and releasing throttle to cycle output on and off. Observe vacuum gauge. Repeat for AM2 solenoid. If either output does not cycle on and off, replace solenoid assembly and repeat QUICK TEST. If both outputs cycle on and off, go to next step.