Test KE: Step 6
6) Check VPWR Circuit Voltage Leave ISC harness disconnected. With KOEO, set DVOM on 20-volt scale. Measure voltage between VPWR circuit at ISC harness connector and battery ground terminal. If reading is less than 10.5 volts, repair open in circuit and repeat QUICK TEST. If reading is 10.5 volts or more, go to next step.