Canister Purge Regulator (CPR) Valve
With CPR valve de-energized, apply 5 in. Hg of vacuum to source port. Valve should not pass air. Apply 9-14 volts to one electrical terminal and ground other. Valve should open and pass air. If valve does not operate as described, replace valve.