Rotor Field Coil Test
NOTE:
Terminal "F" is internal and can be accessed through hole in rear housing of alternator. Be sure ohmmeter probe does not touch alternator housing while performing the following test.
- Disconnect negative battery cable at battery. Disconnect alternator output wire at "B+" terminal. Disconnect alternator wiring plug. Set ohmmeter in "x1" range. Connect one probe to alternator terminal "L" and other probe to terminal "F". See Figure.
- If ohmmeter reading is between 3 and 6 ohms, good alternator field is indicated. Proceed to "L" TERMINAL VOLTAGE TEST . If reading is less than 3 ohms or more than 6 ohms, problem is indicated in field rotor, slip rings or brushes. Remove alternator for further testing. See appropriate tests under BENCH TESTS .