Fuel Level Gauge For Submerged Pump Assembly
REMOVAL
- Remove the fuel pump module. Refer to MODULE, FUEL PUMP, REMOVAL AND INSTALLATION .
- Disconnect the electrical connections (1).
- Lift the tab (1a) and remove the connector plate together with the float (1b).
INSTALLATION
- Place the connector plate together with the float in its housing.
- Install the fuel pump module. Refer to MODULE, FUEL PUMP, REMOVAL AND INSTALLATION .