Mike's Workshop Manuals: Service manuals for every vehicle
Home >> Fiat >> 2015 >> 500L Easy, Standard Trans >> Repair and Diagnosis >> Engine Performance >> Ignition System - (Service Information) - 500L >> Sensor, Knock >> Operation >> Operation

Sensor, Knock: Operation: Operation

Fig 1: Electrical Polarization Operation
GC0152782Courtesy of CHRYSLER GROUP, LLC

The molecules of a quartz crystal are affected by electrical polarization. In rest conditions (A) the molecules are not arranged in a particular way. When the crystal is subjected to pressure or to an impact (B), the higher the pressure, the more marked their arrangement. This arrangement produces a voltage at the ends of the crystal.