Diagnosis And Testing - Power Window Switch
Test the power window switch continuity. Refer to the Power Window Switch Continuity chart to determine if the continuity is correct in the Off, Up and Down switch positions. See Fig 1.
POWER WINDOW SWITCH CONTINUITY CHART
| SWITCH POSITION | CONTINUITY BETWEEN |
| UP | PIN 1 AND 3 |
| - | PIN 2 AND 4 |
| DOWN | PIN 1 AND 4 |
| - | PIN 2 AND 5 |
| NEUTRAL (OFF) | PIN 1 AND 3 |
| - | PIN 2 AND 5 |