GENERATOR

MANUFACTURER ENGINE NOMINAL RATING MINIMUM OUTPUT (AMPS) (@ SPECIFIED TEST CONDITIONS)
MITSUBISHI ELECTRIC 2.4L 120A 70A
DENSO 2.7, 3.5L 140A 90A
BOSCH 2.0L Diesel 150A 100A
TEST CONDITIONS
1. Engine RPM : 2500 RPM (ENGINE HOT)
2. Voltage Output : 13.0 - 16.0 V