When Monitored and Set Condition

  1. When Monitored: Engine Running. Cold start test. Fuel Level greater than 12%. Ambient Temperature between 4°C and 32°C (39°F and 89°F) Close Loop fuel system. Test runs when small leak test is maturing.
  2. Set Condition: The PCM activates the Evap Purge Solenoid to pull the Evap system into a vacuum. The PCM turns the Evap Purge solenoid off to seal the Evap system. If the Fuel Tank Pressure Sensor reads between -1.5 to +1.0 hPa before the calibrated amount of time for a Medium leak/Small leak an error is detected. Two Trip Fault.
Possible CauseS 
EVAPORATIVE EMISSION SYSTEM LEAK
FUEL TANK PRESSURE SENSOR

For a complete Powertrain Control Module Circuit Diagram, (Refer to ENGINE - SCHEMATICS AND DIAGRAMS) .