Power Door Lock Test 6A - Inoperative Door Lock Inhibit Circuit
NOTE:
Perform POWER DOOR LOCK TEST 1A
before proceeding with this test. For connector terminal identification, refer to CONNECTOR IDENTIFICATION
. For wiring diagrams, refer to WIRING DIAGRAMS
. Perform, after each repair, TEST VER-1A - VERIFICATION PROCEDURE
.
CAUTION:
Always turn ignition switch to OFF position prior to disconnecting or connecting any module connector.
- Open left front door and read left front door ajar status. If scan tool displays LF DOOR: CLOSED, go to next step. If scan tool does not display LF DOOR: CLOSED, go to DOOR AJAR TEST 3A .
- Remove key from ignition switch. Using scan tool, read key-in ignition status. If scan tool does not display KEY-IN IGN: CLOSED, go to next step. If scan tool displays KEY-IN IGN: CLOSED, go to CHIME TEST 7A .
- Insert key in ignition switch. Using scan tool, read key-in ignition status. If scan tool displays KEY-IN IGN: CLOSED, replace Body Control Module (BCM). If scan tool does not display KEY-IN IGN: CLOSED, go to CHIME TEST 6A .