Instrument Cluster Test 6A - Gauges Not Going To Zero When Key Is Turned Off
NOTE:
Perform INSTUMENT CLUSTER TEST 1A
before proceeding with this test. For connector terminal identification, see CONNECTOR IDENTIFICATION
For wiring diagrams, refer to WIRING DIAGRAMS
. Perform, after each repair, TEST VER-1A - VERIFICATION PROCEDURE
.
CAUTION:
Always turn ignition switch to OFF position prior to disconnecting or connecting any module connector.
- Turn ignition off. Remove and inspect junction block fuse No. 7. If fuse is blown, go to INSTRUMENT CLUSTER TEST 6B . If fuse is okay, go to next step.
- Disconnect instrument cluster Red connector and ensure connector is clean and not damaged. See Figure in INSTRUMENT CLUSTER TEST 5G. Using external voltmeter, measure voltage at terminal No. 5 (Pink/Red wire) on instrument cluster Red 13-pin connector. If voltage is 10 volts or less, repair open Pink/Red wire. If voltage is more than 10 volts, replace instrument cluster.