Instrument Cluster Test 3D - Temperature Gauge Not Operating Properly
NOTE:
Perform INSTRUMENT CLUSTER TEST 1A before proceeding with this test. For connector terminal identification and wiring diagrams, see CONNECTOR IDENTIFICATION in appropriate BODY CONTROL COMPUTER section in this article. For wiring diagrams, see WIRING DIAGRAMS at the end of article. Perform TEST VER-1A after each repair.
CAUTION:
Always turn ignition switch to OFF position prior to disconnecting or connecting any module connector.
- Using scan tool, read engine trouble codes. If codes related to engine coolant temperature are displayed, See appropriate articles; For Sebring Convertible 2.4L TESTS W/CODES - 2.4L article, For Sebring Convertible 2.5L TESTS W/CODES - 2.5L article. If no codes are displayed, go to next step.
- Using scan tool, actuate instrument cluster gauges. Temperature gauge should move to HOT mark, then in steps should move to 1/2, COLD marks. If temperature gauge functions as described, replace BCM. If temperature gauge does not function correctly, go to next step.
- Remove instrument cluster and access back of gauges. Using external ohmmeter, measure resistance across temperature gauge terminals at 12 and 6 o/clock, and 3 and 9 o/clock. If resistance is 200-220 ohms, replace instrument cluster circuit board. If resistance is not 200-220 ohms, replace temperature gauge.