Interior Light Test 5A - Illuminated Entry Inoperative
NOTE:
Perform INTERIOR LIGHT TEST 1A
before proceeding with this test. For connector terminal identification, see CONNECTOR IDENTIFICATION in BODY CONTROL COMPUTER INTRODUCTION. Perform TEST VER-1A
after each repair.
CAUTION:
Always turn ignition switch to OFF position prior to disconnecting or connecting any module connector.
NOTE:
Illuminated entry will only operate when activated by Remote Keyless Entry (RKE) transmitter.
Ensure dome light switch is in the middle position before proceeding. Using scan tool, actuate courtesy light. If dome light does not come on, go to INTERIOR LIGHT TEST 7A . If dome light comes on, stop actuation. If RKE is not operating properly, go to POWER DOOR LOCK TEST 8A . If RKE is operating properly, replace BCM.