TEST 15A - Key In Ignition
NOTE:
For connector terminal identification, see CONNECTOR IDENTIFICATION. For wiring diagram, see WIRING DIAGRAMS at the end of this article. Perform VERIFICATION PROCEDURE VER-1 after each repair.
CAUTION:
Always turn ignition switch to OFF position prior to disconnecting or connecting any module connector.
- Ensure ignition switch is in ON position. Using DRB-II, select KEY IN IGNITION SWITCH status. If DRB-II displays KEY IN IGN: CLOSED, go to step 5). If DRB-II does not display KEY IN IGN: CLOSED, go to next step.
- Turn ignition switch to OFF position. Disconnect key in light switch connector. Check, clean and repair connections as needed. Connect jumper wire between key in light switch connector terminal No. 3 (Light Blue wire) and terminal No. 4 (Black/Orange wire). Ensure driver's door is open. If DRB-II displays KEY IN IGN: CLOSED, replace key in light switch. If DRB-II does not display KEY IN IGN: CLOSED, go to next step.
- Disconnect jumper wire. Connect jumper wire between key in light switch connector terminal No 3 (Light Blue wire) and ground. If DRB-II displays KEY IN IGN: CLOSED, repair Black/Orange wire between key in light switch connector and ground for short to ground. If DRB-II does not display KEY IN IGN: CLOSED, go to next step.
- Disconnect jumper wire. Gain access to body control module, located behind right kick panel. With connectors connected, connect jumper wire between body control module Black connector terminal No. 2 (Light Blue wire) and ground. If DRB-II displays KEY IN IGN: CLOSED, repair open in Light Blue wire between body control module Black connector and key in light switch connector.
- If DRB-II displays KEY IN IGN: CLOSED in step 1), ensure left door is open. Remove key from ignition switch. If DRB-II displays CIRCUIT OPEN, go to TEST 30A. If DRB-II does not display CIRCUIT OPEN, go to next step.
- Disconnect key in light switch connector. Check, clean and repair connections as needed. If DRB-II does not display KEY IN IGN: CLOSED, replace key in light switch. If DRB-II displays KEY IN IGN: CLOSED, go to next step.
- Disconnect body control module. Check, clean and repair connections as needed. Put DRB-II in ohmmeter mode. Measure resistance at body control module Black connector terminal No. 2 (Light Blue wire). If resistance is less than 5 ohms, repair Light Blue wire between body control module Black connector and key in light switch connector for short to ground. If resistance is more than 5 ohms, replace body control module.