TEST 59A - Washer Fluid Switch Circuit
NOTE:
For connector terminal identification, see CONNECTOR IDENTIFICATION . For wiring diagrams, see appropriate chassis wiring diagram in the WIRING DIAGRAMS Section.
- Check washer fluid level. If washer fluid is low, add fluid as necessary. Perform VERIFICATION TEST VER-1 . If fluid level is okay, read washer fluid switch status using DRB-II. If DRB-II displays CIRCUIT OPEN, go to step 5). If DRB-II does not display CIRCUIT OPEN, disconnect washer fluid level switch connector. If DRB-II displays CIRCUIT OPEN, replace washer fluid level switch. Perform VERIFICATION TEST VER-1 . If DRB-II does not display CIRCUIT OPEN, turn ignition switch to OFF position.
- Disconnect both body controller connectors. Body controller is located behind right side kick panel. Check condition of connectors, and clean or repair connectors as necessary. Put DRB-II in ohmmeter mode. Probe terminal No. 19 (Black/Tan wire) of body controller Red connector.
- If resistance is less than 5 ohms, repair short to ground in Black/Tan wire between body controller and washer fluid level switch connector. Perform VERIFICATION TEST VER-1 . If resistance is more than 5 ohms, replace body controller. Perform VERIFICATION TEST VER-1 .
- If DRB-II displays CIRCUIT OPEN in step 1), disconnect washer fluid level switch connector. Connect a jumper wire between Black/Tan wire and Black wire of washer fluid level switch connector. If DRB-II displays CIRCUIT CLOSED, replace washer fluid level switch. Perform VERIFICATION TEST VER-1 . If DRB-II does not display CIRCUIT CLOSED, disconnect jumper wire.
- Connect jumper wire between Black/Tan wire of washer fluid level switch connector and ground. If DRB-II displays CIRCUIT CLOSED, repair open in Black wire between washer fluid level switch connector and ground. Perform VERIFICATION TEST VER-1 . If DRB-II does not display CIRCUIT CLOSED, disconnect both body controller connectors.
- Body controller is located behind right side kick panel. Check condition of connectors, and clean or repair connectors as necessary. Reconnect both body controller connectors. Connect a jumper wire between terminal No. 19 (Black/Tan wire) at wiring harness side of body controller Red connector and ground.
- If DRB-II displays CIRCUIT CLOSED, repair open Black/Tan wire between washer fluid level switch connector and body controller connector. Perform VERIFICATION TEST VER-1 . If DRB-II does not display CIRCUIT CLOSED, replace body controller. Perform VERIFICATION TEST VER-1 .