TEST 17C - Electronic Instrument Cluster Switch Test

  1. Using DRB-II, read electronic instrument trip reset switch status. If DRB-II displays CIRCUIT CLOSED, replace electronic instrument cluster. Perform VERIFICATION TEST VER-1 . If DRB-II does not display CIRCUIT CLOSED, press TRIP RESET button on electronic instrument cluster.
  2. If DRB-II does not display CIRCUIT CLOSED, replace electronic instrument cluster. Perform VERIFICATION TEST VER-1 . If DRB-II displays CIRCUIT CLOSED, read electronic instrument cluster trip switch status using DRB-II.
  3. If DRB-II displays CIRCUIT CLOSED, replace electronic instrument cluster. Perform VERIFICATION TEST VER-1 . If DRB-II does not display CIRCUIT CLOSED, press trip reset button on electronic instrument cluster. If DRB-II does not display CIRCUIT CLOSED, replace electronic instrument cluster. Perform VERIFICATION TEST VER-1 .
  4. If DRB-II displays CIRCUIT CLOSED, read electronic instrument cluster US/metric switch status using DRB-II. If DRB-II displays CIRCUIT CLOSED, replace electronic instrument cluster. Perform VERIFICATION TEST VER-1 . If DRB-II does not display CIRCUIT CLOSED, press US/METRIC button on electronic instrument cluster.
  5. If DRB-II does not display CIRCUIT CLOSED, replace electronic instrument cluster. Perform VERIFICATION TEST VER-1 . If DRB-II displays CIRCUIT CLOSED, replace body controller. Perform VERIFICATION TEST VER-1 .