Installation Procedure
- Clean the sealing surfaces.
Install a NEW vacuum pump gasket.
- Install the vacuum pump (1).
- Vacuum Pump Bolt (2) - Tighten [3x]
Tighten
- First Pass: 15 N.m (11 lb ft)
- Final Pass: 25 N.m (18 lb ft)
Install the surge tank fixing bolts and tighten to 5 N.m (44 lb in)
Install the brake booster vacuum pipe (1) to the vacuum pump. Refer to Plastic Collar Quick Connect Fitting Service .
CAUTION:
Refer to Fastener Caution