Mike's Workshop Manuals: Service manuals for every vehicle
Home >> Chevrolet >> 2018 >> Volt Premier >> Repair and Diagnosis >> Engine Performance >> Engine Control Systems >> Engine Controls And Fuel System- - 1.5L (L3A) - Repair Instructions >> Repair Instructions >> Exhaust Gas Recirculation Cooler Outlet Pipe Replacement >> Installation Procedure

Installation Procedure

  1. GM4091558Courtesy of GENERAL MOTORS COMPANY

    Install a NEW seal. (1, 3) [2x]

  2. Exhaust Gas Recirculation Cooler Outlet Pipe (2) - Install
  3. GM4091555Courtesy of GENERAL MOTORS COMPANY
    NOTE:

    Do NOT tighten.

    Exhaust Gas Recirculation Pipe Bolt (1) - Install [2x]

  4. GM4091535Courtesy of GENERAL MOTORS COMPANY
    NOTE:

    Do NOT tighten.

    Exhaust Gas Recirculation Pipe Bolt (3)@Exhaust Gas Recirculation Cooler (1) - Install [2x]

  5. Exhaust Gas Recirculation Pipe Bolt (3) - Tighten [2x] 10N.m (89 lb in)
  6. GM4091555Courtesy of GENERAL MOTORS COMPANY

    Exhaust Gas Recirculation Cooler Bolt (1) - Tighten [2x] 10N.m (89 lb in)

  7. GM4091535Courtesy of GENERAL MOTORS COMPANY

    Install the exhaust gas recirculation temperature sensor - position 2 (2) and tighten to 42N.m (31 lb ft).

  8. Three-Way Catalytic Converter Replacement - Install
  9. Water Outlet Replacement - Install
  10. Air Cleaner Outlet Duct Replacement  - Install
  11. Dash Upper Extension Panel Opening Cover Replacement - Install