Diagnostic Information and Procedures
>>
DTC P111E
>>
Typical Scan Tool Data
Typical Scan Tool Data
ECT Sensor Temperature
Circuit
Short to Ground
Open
Short to Voltage
Operating Conditions:
Engine Running
Parameter Normal Range:
-39 to +120°C (-38 to +248°F)
ECT Sensor
150°C (302°F)
-40°C (-40°F)
-40°C (-40°F)
Low Reference
-
-40°C (-40°F)
-40°C (-40°F)