Heated Oxygen Sensor Replacement - Sensor 1
| Callout | Component Name |
|---|---|
|
WARNING:
In order to avoid being burned, do not service the exhaust system while it is still hot. Service the system when it is cool.
WARNING:
Preliminary Procedure Intake Manifold Cover ReplacementAvoid contact with HOT components. Wear safety glasses and protective gloves to avoid personal injury. |
|
| 1 | Wiring Harness Clip Procedure Remove the heated oxygen sensor wiring from the wiring harness clip. |
| 2 | Electrical Connector |
| 3 | Heated Oxygen Sensor
CAUTION:
Refer to Component Fastener Tightening Caution .
CAUTION:
Refer to Heated Oxygen and Oxygen Sensor Caution .
CAUTION:
Refer to Heated Oxygen Sensor Resistance Learn Reset Caution .
CAUTION:
The use of excessive force may damage the threads in the exhaust manifold/pipe.
CAUTION:
A special anti-seize compound is used on the oxygen sensor threads. New service sensors should already have the compound applied to the threads. Coat the threads of a reused sensor with anti-seize compound P/N 5613695 or equivalent. Procedure If replacing, perform the HO2S heater resistance learned values reset. HO2S Heater Resistance Learned Values Reset
NOTE:
Tighten 42 N.m (31 lb ft) Special Tools EN-48259 Heated Oxygen Sensor Remover/Installer Equivalent regional tools: Special Tools (Mechanical Tools)Special Tools (Diagnostic Tools) |