Mike's Workshop Manuals: Service manuals for every vehicle
Home >> Chevrolet >> 2017 >> Volt Premier >> Repair and Diagnosis >> Hybrid/Electric Powertrain >> Cooling Systems >> Hybrid/EV System Heating And Cooling >> Repair Instructions >> Drive Motor Generator Control Module Cooling Outlet Hose Replacement (Underbody Line to Traction Power Inverter Module Inlet) >> Installation Procedure

Installation Procedure

    Fig 1: Coolant Hose And Clamp
    GM4091181Courtesy of GENERAL MOTORS COMPANY
  1. Install Drive Motor Generator Control Module Cooling Outlet Hose (1)
  2. Install Clamp (2)
  3. Install Front Wheelhouse Liner Replacement (Left Side)Front Wheelhouse Liner Replacement (Right Side)
  4. Lower the vehicle.
  5. Fig 2: Drive Motor Generator Control Module Cooling Outlet Hose And Bolts
    GM4091180Courtesy of GENERAL MOTORS COMPANY
  6. Install a NEW seal.(2)
  7. Install Drive Motor Generator Control Module Cooling Outlet Hose Bolt(1) and tighten 9 N.m (80 lb in)
  8. Fig 3: Clamp And Coolant Hose
    GM4091179Courtesy of GENERAL MOTORS COMPANY
  9. Install Coolant Hose (1)
  10. Install Clamp (2)BO-38185  pliers
  11. Fig 4: Electrical Connector
    GM4091178Courtesy of GENERAL MOTORS COMPANY
  12. Connect Electrical Connector (1, 2)
  13. Fill the cooling system. Drive Motor Generator Power Inverter Module Cooling System Draining and Filling