Circuit/System Description
The power take-off (PTO) is an upfitter integrated system that allows the user to create an auxiliary power source. The PTO system specifically controls engine speed to values higher than normal base idle, PTO load relay engagement and remote starting and shutdown of the engine. When the operator requests PTO using either the PTO switch or PTO remote, the engine RPM will increase to a default standby speed. The engine control module (ECM) converts the data from the engine speed sensor to a 2 pulses/engine revolution signal. When PTO is engaged, the power take-off control module sends a serial data message to the ECM requesting engine speeds, in accordance to signals from the PTO switch or remote.