Without Carbon Pile Tester
- Vehicle ON.
- Verify the scan tool Hybrid Powertrain Control Module Ignition 1 Signal parameter continually increases when controlling the Hybrid Powertrain Control Module 14 V Power Module Setpoint from 10-80% with a scan tool. It may take up to 10 s for battery voltage to stabilize between each setpoint change.
- If the battery voltage does not continually increase
Replace the K1 14V Power Module.
- If the battery voltage continually increases
- If the battery voltage does not continually increase
- All OK.