Liftgate Unlatch Switch
- Ignition OFF, disconnect the harness connector at the S46B Liftgate Unlatch Switch.
- Test for infinite resistance between the signal terminal 2 and the ground terminal 4 with the switch in the open position.
- If less than infinite resistance
Replace the S46B Liftgate Unlatch Switch.
- If infinite resistance
- If less than infinite resistance
- Test for infinite resistance between the signal terminal 3 and the ground terminal 4 with the switch in the open position.
- If less than infinite resistance
Replace the S46B Liftgate Unlatch Switch.
- If infinite resistance
- If less than infinite resistance
- Test for less than 2 Ω between the signal terminal 2 and the ground terminal 4 with the switch in the Lock position.
- If 2 Ω or greater
Replace the S46B Liftgate Unlatch Switch.
- If less than 2 Ω
- If 2 Ω or greater
- Test for less than 2 Ω between the signal terminal 3 and the ground terminal 4 with the switch in the Unlock position.
- If 2 Ω or greater
Replace the S46B Liftgate Unlatch Switch.
- If less than 2 Ω
- If 2 Ω or greater
- All OK