Component Testing
Door Lock Switch
- Ignition OFF, disconnect the harness connector at the appropriate door lock switch.
- Test for infinite resistance between the signal terminals D and E and the ground terminal B with the switch in the open position.
- If not the specified value, replace the door lock switch.
- Test for less than 2 Ω between the signal terminal D and the ground terminal B with the switch in the lock position.
- If greater than the specified range, replace the door lock switch.
- Test for less than 2 Ω between the signal terminal E and the ground terminal B with the switch in the unlock position
- If greater than the specified range, replace the door lock switch.
Door Lock Assembly
- Ignition OFF, disconnect the harness connector at the appropriate door lock.
- Install a 15A fused jumper wire between one of the control terminals and 12V. Momentarily install a jumper wire between the other control terminal and ground. Reverse the jumper wires at least two times, the door lock should perform the LOCK and UNLOCK functions.
- If it does not perform as specified, replace the door lock.