Typical Scan Tool Data
MAP Sensor
| Circuit | Short to Ground | Open | Short to Voltage |
|---|---|---|---|
| Operating Conditions:
Engine running at various operating conditions Parameter Normal Range: 12-103 kPa (1.7-14.9 PSI) |
|||
| 5-Volt Reference | 0 kPa (0 PSI) | 0 kPa (0 PSI) | 104 kPa (15.1 PSI) |
| Signal | 0 kPa (0 PSI) | 0 kPa (0 PSI) | 104 kPa (15.1 PSI)* |
| Low Reference | - | 80-103 kPa (11.6-14.9 PSI) | - |
| * Internal ECM or sensor damage may occur if the circuit is shorted to B+. | |||