Removal Procedure
- Disconnect the battery negative cable. Refer to Battery Negative Cable Disconnection and Connection .
- Remove the turbocharger wastegate actuator vacuum control solenoid valve splash shield. Refer to Turbocharger Wastegate Actuator Vacuum Control Solenoid Valve Splash Shield Replacement .
- Loosen the exhaust gas recirculation valve temperature sensor (2), use a suitable tool (1), e.g. a crow foot.
- Disconnect the exhaust gas recirculation valve temperature sensor wiring harness plug (2).
- Remove the exhaust gas recirculation valve temperature sensor wiring harness plug (2) out of the retainer (3).
- Remove the exhaust gas recirculation valve temperature sensor (1).
WARNING:
In order to avoid being burned, do not service the exhaust system while it is still hot. Service the system when it is cool.