Removal Procedure
- Before performing the first steps, review the Emission Reduction Fluid and Emission Reduction Fluid Handling .
- Remove the emission reduction fluid tank insulator - upper. Refer to Emission Reduction Fluid Tank Insulator Replacement - Upper .
- Disconnect the 6 emission reduction fluid pump module wiring harness plugs.
- Disconnect the emission reduction fluid pump module wiring harness plug (1) from the body wiring harness.
- Cut and DISCARD the 4 cable ties.
- Remove the emission reduction fluid pump module wiring harness (2).