Mike's Workshop Manuals: Service manuals for every vehicle
Home >> Chevrolet >> 2012 >> Traverse LS, AWD >> Repair and Diagnosis >> Engine Performance >> System >> Engine Controls/Fuel - 3.6L - DTC P0010 To DTC P0338 >> Diagnostic Information and Procedures >> DTC P0192 or P0193 >> Circuit/System Testing

Circuit/System Testing

  1. Ignition OFF, disconnect the multi-way harness connector X161 at the rear of the intake manifold.
  2. NOTE:

    Testing for steps 2 through 5 is performed on the ECM side of the multi-way harness connector.

  3. Ignition OFF, and all vehicle systems OFF. It may take up to 2 minutes for all vehicle systems to power down. Test for less than 5 Ω between the low reference circuit terminal 5 and ground.
    • If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the K20 ECM.
  4. Ignition ON, test for 4.8-5.2 V between the 5 V reference circuit terminal 11 and ground.
    • If less than the specified range, test the 5 V reference circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the K20 ECM.
    • If greater than the specified range, test the 5 V reference circuit for a short to voltage. If the circuit tests normal, replace the K20 ECM.
  5. Ignition ON, verify the scan tool Fuel Rail Pressure Sensor voltage parameter is less than 0.02 V.
    • If greater than the specified value, test the signal circuit for a short to voltage. If the circuit tests normal, replace the K20 ECM.
  6. Connect a 3 A fused jumper wire between the signal circuit terminal 12 and the 5 V reference circuit terminal 11. Verify the scan tool Fuel Rail Pressure Sensor Voltage parameter is greater than 4.96 V.
    • If less than the specified value, test the signal circuit for an open/high resistance or a short to ground. If the circuit tests normal, replace the K20 ECM.
  7. Ignition OFF, remove the intake manifold.
  8. Connect the multi-way harness connector X161.
  9. Disconnect the B47B fuel rail pressure sensor connector.
  10. NOTE:

    Testing for steps 9 through 12 are performed at the fuel rail pressure sensor connector.

  11. Ignition OFF, and all vehicle systems OFF. It may take up to 2 minutes for all vehicle systems to power down. Test for less than 5 Ω between the low reference circuit terminal 1 and ground.
    • If greater than the specified range, test the low reference circuit for an open/high resistance.
  12. Ignition ON, test for 4.8-5.2 V between the 5 V reference circuit terminal 3 and ground.
    • If less than the specified range, test the 5 V reference circuit for a short to ground or an open/high resistance.
    • If greater than the specified range, test the 5 V reference circuit for a short to voltage.
  13. Ignition ON, verify the scan tool Fuel Rail Pressure Sensor voltage parameter is less than 0.02 V.
    • If greater than the specified value, test the signal circuit for a short to voltage.
  14. Connect a 3 A fused jumper wire between the signal circuit terminal 2 and the 5 V reference circuit terminal 3. Verify the scan tool Fuel Rail Pressure Sensor Voltage parameter is greater than 4.96 V.
    • If less than the specified value, test the signal circuit for an open/high resistance or a short to ground.
  15. If all circuits test normal, replace the B47B fuel rail pressure sensor.