Typical Scan Tool Data
MAP Sensor
| Circuit | Short to Ground | Open | Short to Voltage |
|---|---|---|---|
| Operating Conditions:
Engine running at various operating conditions Parameter Normal Range: 12-225 kPa (1.7-32.6 psi) |
|||
| 5 V Reference | 0 kPa (0 psi) | 0 kPa (0 psi) | 255 kPa (36.9 psi) |
| Signal | 0 kPa (0 psi) | 0 kPa (0 psi) | 255 kPa (36.9 psi)* |
| Low Reference | - | 255 kPa (36.9 psi) | - |
| *Internal ECM or sensor damage may occur if the circuit is shorted to B+. | |||