Circuit/System Testing
- Ignition OFF, disconnect the harness connector at the Q13 evaporative emission system vent solenoid valve.
- Verify that a test lamp illuminates between the voltage supply circuit terminal 2 and ground.
- If the test lamp does not illuminate, test the voltage supply circuit for a short to ground or an open/high resistance. If the circuit tests normal and the voltage supply circuit fuse is not open, test or replace the Q13 evaporative emission system vent solenoid valve.
- Connect a test lamp between the voltage supply circuit terminal 2 and the control circuit terminal 1.
- Command the EVAP leak detection pump ON and OFF with a scan tool. The test lamp should respond to the command.
- If the test lamp is always ON, test the control circuit for a short to ground. If the circuit tests normal, replace the K20 engine control module.
- If the test lamp is always OFF, test the control circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the K20 engine control module.
- If all circuits test normal, replace the Q13 evaporative emission system vent solenoid valve.