Circuit/System Verification
NOTE:
Larger volume fuel tanks and/or those with lower fuel levels may require several minutes for the floating indicator to stabilize. Refer to EN 41413-200:
Evaporative Emissions System Tester operation manual for detailed instructions in Evaporative Emission Control System Diagnosis
.
- Connect the EN 41413-200: nitrogen/smoke hose to the EN 41413-311: brass cone adapter. Disconnect the hose at the fuel cap end of the GE 41415-30: fuel tank cap adapter. Connect the EN 41413-311: brass cone adapter to the disconnected hose on the GE 41415-30: fuel tank cap adapter. Install the GE 41415-30: fuel tank cap adapter filler neck end only to the vehicle.
- Be sure the EVAP leak detection pump switching valve is in the vent position.
- Use the flow meter on the EN 41413-200:
EEST calibrated to 0.51 mm (0.020 in) to determine there is no leak in the EVAP system.
- If a leak is detected, use the EN 41413-200: EEST to apply smoke to the EVAP system at the filler neck until the leak is located.