Circuit/System Testing
- Ignition OFF, disconnect the harness connector at the liftgate actuator switch.
- Test for less than 10 Ω between the low reference circuit terminal 2 and ground.
- If greater than the specified range, test the low reference circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the liftgate control module.
- Ignition ON, verify that the scan tool LGM Full Open Switch parameter is Inactive.
- If not the specified value, test the signal circuit terminal 1 for a short to ground. If the circuit tests normal, replace the liftgate control module
- Connect a 3 A fused jumper wire between the signal circuit terminal 1 and ground, verify that the scan tool LGM Full Open Switch parameter is Active
- If not the specified value, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the liftgate control module
- If all circuits test normal, replace the liftgate actuator switch.