Circuit/System Testing
- Verify that DTC P0562 is not set.
- Ignition OFF, disconnect the harness connectors at the FPCM, and X2 at the FPCM relay.
- Connect a test lamp between the appropriate IGN voltage circuit terminals listed below and ground.
- FPCM terminal 15
- FPCM relay terminal 5
- Ignition ON, verify the test lamp turns on.
- If the test lamp is OFF, test the IGN voltage circuit a short to ground or an open/high resistance.
- Ignition OFF, connect the harness connector at the FPCM.
- Connect a test lamp between the X2 FPCM relay harness connector terminal 5 and ground.
- Ignition ON, verify the test lamp is ON.
- If the test lamp is OFF, test the IGN voltage circuit an open/high resistance. If the circuit tests normal, replace the FPCM.
- If all circuits test normal, replace the FPCM relay.