Circuit/System Testing
NOTE:
You must perform the Circuit/System Verification before proceeding with Circuit/System Testing.
- Ignition OFF, disconnect the harness connector at the E24 intake air heater.
- Ignition ON, test for less than 2 V between the Intake Air Heater Switch On/Off Signal circuit terminal 2 and ground.
- If greater than the specified value, test the Intake Air Heater Switch On/Off Signal circuit for a short to voltage. If the circuit tests normal, replace the K34 glow plug control module.
- If less than the specified value, replace the E24 intake air heater.