Circuit/System Testing
- Engine running, observe the Cyl 1-8 IC Ckt. Gnd Test Status on the scan tool. Test Status should be OK or Not Run.
- If test status is Fault test for open or short to ground.
- Engine running, observe the Cyl 1-8 IC Ckt. Open Test Status on the scan tool. Test Status should be OK or Not Run.
- If test status is Fault test for open circuit.
- Engine running, observe the Cyl 1-8 IC Ckt. Short Volts Test Status on the scan tool. Test Status should be OK or Not Run.
- If test status is Fault test for short to voltage.
- Ignition OFF, disconnect the harness connector at the appropriate T8 ignition coil.
- Ignition ON, verify that a test lamp illuminates between the ignition voltage circuit terminal D and ground.
- If the test lamp does not illuminate, test the circuit for a short to ground or an open/high resistance. If the circuit tests normal and the ignition circuit fuse is open, test all the components connected to the ignition voltage circuit and replace as necessary.
- Connect a test lamp between the each of the ground circuits terminal A, and terminal B, and B+. The test lamp should illuminate on each circuit.
- If the test lamp does not illuminate, test the suspected circuit for an open/high resistance.
- If all circuits test normal, test or replace the T8 ignition coil.
NOTE:
The ignition circuit supplies voltage to other components. Make sure you test all circuits for a short to ground or test all components for being shorted that share the ignition circuit.