Installation Procedure
- Install and tighten the bank 1 knock sensor (1) to 25 N.m (18 lb ft) .
- Connect the engine harness electrical connector (1) to the knock sensor.
- Install the radiator air baffle. Refer to Radiator Air Baffle Assemblies and Deflectors .
- Lower the vehicle.
CAUTION:
Refer to Fastener Caution
.
NOTE:
DO NOT apply thread sealant to the sensor threads. The sensor threads are coated at the factory. Applying additional sealant affects the sensors ability to detect detonation.