Component Testing
Static Test
- Ignition OFF, disconnect the harness connector at the high pressure fuel pump.
- Test for 0.49 Ω plus/minus 0.023 Ω at 20°C (68°F) between FRP regulator low circuit terminal 1 and FRP regulator hi circuit terminal 2.
- If not within the specified range, replace the high pressure fuel pump.
- Measure the resistance between each terminal and the high pressure fuel pump housing. The DMM should display OL Ω.
- If less than the specified value, replace the high pressure fuel pump.
NOTE:
The DMM and test leads must be calibrated to 0 ohms in order to prevent misdiagnosis.