Removal Procedure
- Remove the fuel tank. Refer to Fuel Tank Replacement .
- Remove the fuel feed (1) and evaporative emission (EVAP) (2) lines from the fuel sender assembly. Refer to Plastic Collar Quick Connect Fitting Service .
- Use the J 45722 and a long breaker-bar in order to unlock the fuel sender lock ring. Turn the fuel sender lock ring in a counterclockwise direction.
- Remove the fuel sender assembly (2) and seal (3). Discard the seal.
- Clean the fuel sender sealing surfaces (4).
- Some lock ring were manufactured with DO NOT REUSE stamped into them. These lock rings may be reused if they are not damaged or warped.
- Inspect the lock ring for damage due to improper removal or installation procedures. If damage is found, install a NEW lock ring.
- Check the lock ring for flatness.
- Place the lock ring on a flat surface. Measure the clearance between to lock ring and the flat surface using a feeler gage at 7 points.
- If the warpage is less than 0.41 mm (0.016 in), the lock ring does not require replacement.
- If the warpage is greater than 0.41 mm (0.016 in), the lock ring must be replaced.
CAUTION:
Avoid damaging the lock ring. Use only J-45722 to prevent damage to the lock ring.
CAUTION:
Do Not handle the fuel sender assembly by the fuel pipes. The amount of leverage generated by handling the fuel pipes could damage the joints.
NOTE:
Do NOT use impact tools. Significant force will be required to release the lock ring. The use of a hammer and screwdriver is not recommended. Secure the fuel tank in order to prevent fuel tank rotation.
WARNING:
Refer to Fuel Storage Warning
.
NOTE: