  1. Install a 10-amp fused jumper wire between the control terminal A and 12 volts. Momentarily install a jumper wire between the control terminal B and ground. The recirculation actuator shaft should rotate.
    • If the function does not perform as specified, replace the recirculation actuator.
  2. Reverse the jumper wires; the recirculation actuator shaft should rotate.
    • If the function does not perform as specified, replace the recirculation actuator.