  1. Ignition OFF, disconnect the harness connector at the recirculation actuator.
  2. Ignition ON, connect a test lamp between the control circuit terminal A and control circuit terminal B. Place the actuator switch in each direction. The test lamp should briefly illuminate when commanding the actuator from one direction to the other.
    • If the test lamp is always OFF, test both control circuits for a short to ground or an open/high resistance. If the circuits test normal, replace the HVAC control module.
    • If the test lamp is always ON, test both control circuits for a short to voltage. If the circuits test normal, replace the HVAC control module.
  3. If all circuits test normal, test or replace the recirculation actuator.